A6 Manual
Details
Intelligent Controller A2/A6/C3-W1/C3-W2
Main features
·Computer main
board & module for industrial & civil pump
·Auto/manual switch
·LCD displays pump
running information
·Under voltage
protection
·Over voltage
protection
·Push button
calibration
·Dry running protection without installing float switch or liquid probe in the well
A2
Main
specifications
·Rated input
voltage: AC220V-240V, single phase
·Rated frequency:
50Hz/60Hz
·Rated output power
of pump motor: 0.37-2.2kW(0.5HP-3HP)
Technical data
·Action time of
short circuit<0.1sec
·Action time of
over current: 5 sec
·Recovery time of
over current: 30 min
·Action time of
dry-running protection: 6 sec
·Recovery time of
dry-running: 30 min
·Double liquid level transfer distance:> 1000m
A6/C3-W1/A8
Main
specifications
·Rated input
voltage: AC380V, three phase
·Rated frequency:
50Hz/60Hz
·Rated output power
of pump motor:
A6:0.75-7.5kW(1HP-10HP)
C3-W1:
0.75-15kW(1HP-20HP)
A8:18.5-30kW(25HP-40HP)
Technical data
·Action time of
short circuit<0.1sec
·Action time of
open phase: <2 sec
·Action time of
over current: 5 sec
·Recovery time of
over current: 30 min
·Action time of
dry-running protection: 6 sec
·Recovery time of
dry-running: 30 min
C3-W2
Main
specifications
·Rated input
voltage: AC380V, three phase
·Rated frequency:
50Hz/60Hz
·Rated output power
of pump motor:
0.75-15kW(1HP-20HP)
Technical data
·Trip response time
of over current: 5sec – 5min
·Trip response time
of open phase: <2 sec
·Trip response time
of short circuit: <0.1sec
·Trip response time
of under volt: <5 sec
·Trip response time
of dry-running: 6sec
·Set voltage of Under.V:
323V
·Recovery time of
over current: 30 min
·Recovery time of
dry-running: 30 min
·Liquid-level
transfer distance: ≤1000m